ISHS


Acta
Horticulturae
Home


Login
Logout
Status


Help

ISHS Home

ISHS Contact

Consultation
statistics
index


Search
 
ISHS Acta Horticulturae 761: XXVII International Horticultural Congress - IHC2006: International Symposium on Advances in Environmental Control, Automation and Cultivation Systems for Sustainable, High-Quality Crop Production under Protected Cultivation

TRANSPIRATION OF TOMATO PLANT CANOPY AND WATER USE FOR A FOG COOLED GREENHOUSE IN SEMIARID CLIMATE

Authors:   S. Sase, M. Ishii, H. Moriyama, C. Kubota, K. Kurata, M. Hayashi, N. Sabeh, P. Romero, G.A. Giacomelli
Keywords:   evapotranspiration, natural ventilation control, tracer gas
Abstract:
The ultimate goal of this collaborative project is to develop an effective environmental control strategy to cool the greenhouses for plant production and minimize the water use in semiarid climate. Using a single-span double-polyethylene greenhouse with tomato plant canopy at The University of Arizona, the canopy transpiration rate and the water balance of greenhouse were investigated. The greenhouse was equipped with high-pressure fog nozzles, roll-up side vents with insect screens, and a roof vent. Fogging was operated cyclically with an air temperature set point of 24°C. Under different vent configurations, the transpiration rate was measured using a stem gage. The amounts of generated fog and non-evaporated water droplets were collected and measured. The natural ventilation rate was measured continuously using SF6 gas as a tracer. Preliminary results showed that the transpiration rate increased linearly with an increase in vapor pressure deficit (VPD) of the air. When the ventilation rate was decreased by reducing the vent openings, the total water use in the greenhouse decreased by 13% and relative humidity increased as expected from simulation based on the steady-state energy balance. The decrease in canopy transpiration was driven by the decrease in VPD, and was at a greater magnitude than that of fog evaporation rate under the present experimental conditions with relatively high humidity ranging 70–94%. These results suggest that by optimizing natural ventilation rate, we could effectively cool the greenhouse with less water use.

Download Adobe Acrobat Reader (free software to read PDF files)

761_5     761     761_7

URL www.actahort.org      Hosted by K.U.Leuven      © ISHS