| Authors: | C.E.L. Oliveira, J.L. García, L.M. Navas, M.A. Muñoz, R.M. Benavente, S. De La Plaza |
| Keywords: | Energy saving, plastics, radiant floor, air heating |
Abstract:
The reduction of the energy consumption for heating is, in many areas, an interesting objective for the production of greenhouses . In this study several techniques of energy saving have been tested using a simple polyethylene cover, in combination with two systems of distribution of the heat: radiant floors and air heaters.
The goal was to verify the efficiency of utilization, on the energy saving aspect, of polyethylene film as a double covering or small tunnel.
The system that got a significant energy saving was the combination of the radiant floor with polyethylene tunnels; the obtained energy saving was 30% as against the use of radiant floor without the tunnels.
It seems advisable then, to use the tunnels with the heating system inside them.
|
Download Adobe Acrobat Reader (free software to read PDF files) |
|